Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 845
Filtrar
1.
Artif Intell Med ; 151: 102869, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38593683

RESUMO

Anaesthesia, crucial to surgical practice, is undergoing renewed scrutiny due to the integration of artificial intelligence in its medical use. The precise control over the temporary loss of consciousness is vital to ensure safe, pain-free procedures. Traditional methods of depth of anaesthesia (DoA) assessment, reliant on physical characteristics, have proven inconsistent due to individual variations. In response, electroencephalography (EEG) techniques have emerged, with indices such as the Bispectral Index offering quantifiable assessments. This literature review explores the current scope and frontier of DoA research, emphasising methods utilising EEG signals for effective clinical monitoring. This review offers a critical synthesis of recent advances, specifically focusing on electroencephalography (EEG) techniques and their role in enhancing clinical monitoring. By examining 117 high-impact papers, the review delves into the nuances of feature extraction, model building, and algorithm design in EEG-based DoA analysis. Comparative assessments of these studies highlight their methodological approaches and performance, including clinical correlations with established indices like the Bispectral Index. The review identifies knowledge gaps, particularly the need for improved collaboration for data access, which is essential for developing superior machine learning models and real-time predictive algorithms for patient management. It also calls for refined model evaluation processes to ensure robustness across diverse patient demographics and anaesthetic agents. The review underscores the potential of technological advancements to enhance precision, safety, and patient outcomes in anaesthesia, paving the way for a new standard in anaesthetic care. The findings of this review contribute to the ongoing discourse on the application of EEG in anaesthesia, providing insights into the potential for technological advancement in this critical area of medical practice.


Assuntos
Anestesia , Eletroencefalografia , Aprendizado de Máquina , Humanos , Eletroencefalografia/métodos , Anestesia/métodos , Processamento de Sinais Assistido por Computador , Monitores de Consciência , Algoritmos
2.
J Clin Monit Comput ; 37(5): 1179-1192, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37395808

RESUMO

Mode decomposition is a method for extracting the characteristic intrinsic mode function (IMF) from various multidimensional time-series signals. Variational mode decomposition (VMD) searches for IMFs by optimizing the bandwidth to a narrow band with the [Formula: see text] norm while preserving the online estimated central frequency. In this study, we applied VMD to the analysis of electroencephalogram (EEG) recorded during general anesthesia. Using a bispectral index monitor, EEGs were recorded from 10 adult surgical patients (the median age: 47.0, and the percentile range: 27.0-59.3 years) who were anesthetized with sevoflurane. We created an application named EEG Mode Decompositor, which decomposes the recorded EEG into IMFs and displays the Hilbert spectrogram. Over the 30-min recovery from general anesthesia, the median (25-75 percentile range) bispectral index increased from 47.1 (42.2-50.4) to 97.4 (96.5-97.6), and the central frequencies of IMF-1 showed a significant change from 0.4 (0.2-0.5) Hz to 0.2 (0.1-0.3) Hz. IMF-2, IMF-3, IMF-4, IMF-5, and IMF-6 increased significantly from 1.4 (1.2-1.6) Hz to 7.5 (1.5-9.3) Hz, 6.7 (4.1-7.6) Hz to 19.4 (6.9-20.0) Hz, 10.9 (8.8-11.4) Hz to 26.4 (24.2-27.2) Hz, 13.4 (11.3-16.6) Hz to 35.6 (34.9-36.1) Hz, and 12.4 (9.7-18.1) Hz to 43.2 (42.9-43.4) Hz, respectively. The characteristic frequency component changes in specific IMFs during emergence from general anesthesia were visually captured by IMFs derived using VMD. EEG analysis by VMD is useful for extracting distinct changes during general anesthesia.


Assuntos
Anestesia Geral , Eletroencefalografia , Adulto , Humanos , Pessoa de Meia-Idade , Sevoflurano , Monitores de Consciência
3.
Br J Anaesth ; 131(2): 196-199, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37198033

RESUMO

Depth of anaesthesia monitors can fail to detect consciousness under anaesthesia, primarily because they rely on the frontal EEG, which does not arise from a neural correlate of consciousness. A study published in a previous issue of the British Journal of Anaesthesia showed that indices produced by the different commercial monitors can give highly discordant results when analysing changes in the frontal EEG. Anaesthetists could benefit from routinely assessing the raw EEG and its spectrogram, rather than relying solely on an index produced by a depth of anaesthesia monitor.


Assuntos
Anestesia , Humanos , Monitores de Consciência , Estado de Consciência , Eletroencefalografia/métodos
4.
Sensors (Basel) ; 22(16)2022 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-36015860

RESUMO

This paper proposed a new depth of anaesthesia (DoA) index for the real-time assessment of DoA using electroencephalography (EEG). In the proposed new DoA index, a wavelet transform threshold was applied to denoise raw EEG signals, and five features were extracted to construct classification models. Then, the Gaussian process regression model was employed for real-time assessment of anaesthesia states. The proposed real-time DoA index was implemented using a sliding window technique and validated using clinical EEG data recorded with the most popular commercial DoA product Bispectral Index monitor (BIS). The results are evaluated using the correlation coefficients and Bland-Altman methods. The outcomes show that the highest and the average correlation coefficients are 0.840 and 0.814, respectively, in the testing dataset. Meanwhile, the scatter plot of Bland-Altman shows that the agreement between BIS and the proposed index is 94.91%. In contrast, the proposed index is free from the electromyography (EMG) effect and surpasses the BIS performance when the signal quality indicator (SQI) is lower than 15, as the proposed index can display high correlation and reliable assessment results compared with clinic observations.


Assuntos
Anestesia , Eletroencefalografia , Monitores de Consciência , Eletroencefalografia/métodos , Eletromiografia , Análise de Ondaletas
5.
Anesth Analg ; 135(4): 855-864, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35767469

RESUMO

BACKGROUND: BIS (a brand of processed electroencephalogram [EEG] depth-of-anesthesia monitor) scores have become interwoven into clinical anesthesia care and research. Yet, the algorithms used by such monitors remain proprietary. We do not actually know what we are measuring. If we knew, we could better understand the clinical prognostic significance of deviations in the score and make greater research advances in closed-loop control or avoiding postoperative cognitive dysfunction or juvenile neurological injury. In previous work, an A-2000 BIS monitor was forensically disassembled and its algorithms (the BIS Engine) retrieved as machine code. Development of an emulator allowed BIS scores to be calculated from arbitrary EEG data for the first time. We now address the fundamental questions of how these algorithms function and what they represent physiologically. METHODS: EEG data were obtained during induction, maintenance, and emergence from 12 patients receiving customary anesthetic management for orthopedic, general, vascular, and neurosurgical procedures. These data were used to trigger the closely monitored execution of the various parts of the BIS Engine, allowing it to be reimplemented in a high-level language as an algorithm entitled ibis. Ibis was then rewritten for concision and physiological clarity to produce a novel completely clear-box depth-of-anesthesia algorithm titled openibis . RESULTS: The output of the ibis algorithm is functionally indistinguishable from the native BIS A-2000, with r = 0.9970 (0.9970-0.9971) and Bland-Altman mean difference between methods of -0.25 ± 2.6 on a unitless 0 to 100 depth-of-anesthesia scale. This precision exceeds the performance of any earlier attempt to reimplement the function of the BIS algorithms. The openibis algorithm also matches the output of the native algorithm very closely ( r = 0.9395 [0.9390-0.9400], Bland-Altman 2.62 ± 12.0) in only 64 lines of readable code whose function can be unambiguously related to observable features in the EEG signal. The operation of the openibis algorithm is described in an intuitive, graphical form. CONCLUSIONS: The openibis algorithm finally provides definitive answers about the BIS: the reliance of the most important signal components on the low-gamma waveband and how these components are weighted against each other. Reverse engineering allows these conclusions to be reached with a clarity and precision that cannot be obtained by other means. These results contradict previous review articles that were believed to be authoritative: the BIS score does not appear to depend on a bispectral index at all. These results put clinical anesthesia research using depth-of-anesthesia scores on a firm footing by elucidating their physiological basis and enabling comparison to other animal models for mechanistic research.


Assuntos
Anestesia , Anestesiologia , Anestésicos , Algoritmos , Monitores de Consciência , Eletroencefalografia
6.
BMC Palliat Care ; 21(1): 86, 2022 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-35610644

RESUMO

BACKGROUND: Bispectral index (BIS) monitoring uses electroencephalographic data as an indicator of patients' consciousness level. This technology might be a useful adjunct to clinical observation when titrating sedative medications for palliative care patients. However, the use of BIS in palliative care generally, and in the UK in particular, is under-researched. A key area is this technology's acceptability for palliative care service users. Ahead of trialling BIS in practice, and in order to ascertain whether such a trial would be reasonable, we conducted a study to explore UK palliative care patients' and relatives' perceptions of the technology, including whether they thought its use in palliative care practice would be acceptable. METHODS: A qualitative exploration was undertaken. Participants were recruited through a UK hospice. Focus groups and semi-structured interviews were conducted with separate groups of palliative care patients, relatives of current patients, and bereaved relatives. We explored their views on acceptability of using BIS with palliative care patients, and analysed their responses following the five key stages of the Framework method. RESULTS: We recruited 25 participants. There were ten current hospice patients in three focus groups, four relatives of current patients in one focus group and one individual interview, and eleven bereaved relatives in three focus groups and two individual interviews. Our study participants considered BIS acceptable for monitoring palliative care patients' consciousness levels, and that it might be of use in end-of-life care, provided that it was additional to (rather than a replacement of) usual care, and patients and/or family members were involved in decisions about its use. Participants also noted that BIS, while possibly obtrusive, is not invasive, with some seeing it as equivalent to wearable technological devices such as activity watches. CONCLUSIONS: Participants considered BIS technology might be of benefit to palliative care as a non-intrusive means of assisting clinical assessment and decision-making at the end of life, and concluded that it would therefore be acceptable to trial the technology with patients.


Assuntos
Atitude Frente a Saúde , Monitores de Consciência , Família , Cuidados Paliativos , Pacientes , Família/psicologia , Grupos Focais , Humanos , Cuidados Paliativos/métodos , Pacientes/psicologia , Pesquisa Qualitativa
7.
J Neurosci Nurs ; 54(1): 30-34, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35007261

RESUMO

ABSTRACT: BACKGROUND: The Bispectral (BIS) monitor is a validated, noninvasive monitor placed over the forehead to titrate sedation in patients under general anesthesia in the operating room. In the neurocritical care unit, there is limited room on the forehead because of incisions, injuries, and other monitoring devices. This is a pilot study to determine whether a BIS nasal montage correlates to the standard frontal-temporal data in this patient population. METHODS: This prospective nonandomized pilot study enrolled 10 critically ill, intubated, and sedated adult patients admitted to the neurocritical care unit. Each patient had a BIS monitor placed over the standard frontal-temporal location and over the alternative nasal dorsum with simultaneous data collected for 24 hours. RESULTS: In the frontal-temporal location, the mean (SD) BIS score was 50.9 (15.0), average minimum BIS score was 47.0 (15.0), and average maximum BIS score was 58.4 (16.7). In the nasal dorsum location, the mean BIS score was 54.8 (21.6), average minimum BIS score was 52.8 (20.9), and average maximum BIS score was 58.0 (22.2). Baseline nonparametric tests showed nonsignificant P values for all variables except for Signal Quality Index. Generalized linear model analysis demonstrated significant differences between the 2 monitor locations (P < .0001). CONCLUSION: The results of this pilot study do not support using a BIS nasal montage as an alternative for patients in the neurocritical care unit.


Assuntos
Monitores de Consciência , Eletroencefalografia , Adulto , Sedação Consciente , Humanos , Hipnóticos e Sedativos , Unidades de Terapia Intensiva , Projetos Piloto , Estudos Prospectivos
8.
J Neurosurg Anesthesiol ; 34(4): 419-423, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34091549

RESUMO

BACKGROUND: The aim of this observational study was to determine whether bilateral bispectral index (BIS) monitoring can detect seizures in epileptic patients. METHODS: Four-channel frontal BIS monitoring and standard 40-channel electroencephalography monitoring were conducted in epileptic patients undergoing evaluation for epilepsy surgery. The BIS numerical value, signal quality index, electromyography, suppression ratio, and color density spectral array were continuously recorded. In patients with electroencephalography-confirmed seizures, the mean value and trend (slope of linear regression) of bilateral BIS monitor parameters were analyzed from 1 minute before to 1 minute after seizure onset. RESULTS: Of 48 patients included in the study, 21 (43.8%) had at least 1 seizure. BIS numerical value was not able to detect focal or focal to bilateral tonic-clonic seizures. Considering all seizures, the only significant differences between recordings 1 minute before and 1 minute after seizure onset were a decrease in the signal quality index slope from 1 hemisphere (0.039±0.297 vs. -0.085±0.321, respectively; P =0.029) and in the mean signal quality index recorded from both hemispheres (left hemisphere: 65.775±30.599 vs. 61.032±26.285; P =0.016 and right hemisphere: 63.244±31.985 vs. 59.837±27.360; 0.029); these differences were not maintained after Hochberg adjustment for multiple comparisons. In seizures occurring during sleep, there was a change in the electromyography slope of 1 hemisphere before and after seizure onset (-0.141±0.176 vs. 0.162±0.140, respectively; P =0.038). There were variable responses in BIS parameters in the 3 patients who developed focal nonconvulsive seizure clusters. CONCLUSION: Bilateral BIS monitoring was not able to detect the occurrence of seizures in epileptic patients.


Assuntos
Epilepsia , Convulsões , Monitores de Consciência , Eletroencefalografia , Epilepsia/diagnóstico , Humanos , Monitorização Fisiológica , Convulsões/diagnóstico
9.
Anesth Analg ; 134(1): 149-158, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34252066

RESUMO

BACKGROUND: Some older adults show exaggerated responses to drugs that act on the brain. The brain's response to anesthetic drugs is often measured clinically by processed electroencephalogram (EEG) indices. Thus, we developed a processed EEG-based measure of the brain's resistance to volatile anesthetics and hypothesized that low scores on it would be associated with postoperative delirium risk. METHODS: We defined the Duke Anesthesia Resistance Scale (DARS) as the average bispectral index (BIS) divided by the quantity (2.5 minus the average age-adjusted end-tidal minimum alveolar concentration [aaMAC] inhaled anesthetic fraction). The relationship between DARS and postoperative delirium was analyzed in 139 older surgical patients (age ≥65) from Duke University Medical Center (n = 69) and Mt Sinai Medical Center (n = 70). Delirium was assessed by geriatrician interview at Duke, and by research staff utilizing the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) instrument at Mt Sinai. We examined the relationship between DARS and delirium and used the Youden index to identify an optimal low DARS threshold (for delirium risk), and its associated 95% bootstrap confidence bounds. We used multivariable logistic regression to examine the relationship between low DARS and delirium risk. RESULTS: The relationship between DARS and delirium risk was nonlinear, with higher delirium risk at low DARS scores. A DARS threshold of 28.755 maximized the Youden index for the association between low DARS and delirium, with bootstrap 95% confidence bounds of 26.18 and 29.80. A low DARS (<28.755) was associated with increased delirium risk in multivariable models adjusting for site (odds ratio [OR] [95% confidence interval {CI}] = 4.30 [1.89-10.01]; P = .001), or site-plus-patient risk factors (OR [95% CI] = 3.79 [1.63-9.10]; P = .003). These associations with postoperative delirium risk remained significant when using the 95% bootstrap confidence bounds for the low DARS threshold (P < .05 for all). Further, a low DARS (<28.755) was associated with delirium risk after accounting for opioid, midazolam, propofol, phenylephrine, and ketamine dosage as well as site (OR [95% CI] = 4.21 [1.80-10.16]; P = .002). This association between low DARS and postoperative delirium risk after controlling for these other medications remained significant (P < .05) when using either the lower or the upper 95% bootstrap confidence bounds for the low DARS threshold. CONCLUSIONS: These results demonstrate that an intraoperative processed EEG-based measure of lower brain anesthetic resistance (ie, low DARS) is independently associated with increased postoperative delirium risk in older surgical patients.


Assuntos
Anestésicos/farmacologia , Encéfalo/patologia , Eletroencefalografia/métodos , Delírio do Despertar/fisiopatologia , Complicações Pós-Operatórias/fisiopatologia , Idoso , Anestesia Geral/efeitos adversos , Antagonistas Colinérgicos/farmacologia , Monitores de Consciência , Delírio do Despertar/diagnóstico , Feminino , Humanos , Unidades de Terapia Intensiva , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Período Perioperatório , Complicações Pós-Operatórias/diagnóstico , Estudos Prospectivos , Risco , Fatores de Risco
10.
Sci Rep ; 11(1): 24126, 2021 12 16.
Artigo em Inglês | MEDLINE | ID: mdl-34916554

RESUMO

To continuously and noninvasively monitor the cerebral tissue oxygen saturation (StO2) and hemoglobin concentration (gasHb) in cardiac surgery patients, a method combining the use of a cerebral tissue oximeter using near infrared time-resolved spectroscopy (tNIRS-1) and the bispectral index (BIS) was developed in this study. Moreover, the correlation between the estimated hemoglobin concentration (estHb), measured via tNIRS-1, and the hemoglobin concentration (gasHb), analyzed using a blood gas analyzer, were compared. The relationship between the BIS and gasHb was also examined. Through the comparison of BIS and StO2 (r1), and estHb and gasHb (r2), the correlation between the two was clarified with maximum r1 and r2 values of 0.617 and 0.946, respectively. The relationship between BIS and gasHb (r3), showed that there was a favorable correlation with a maximum r3 value of 0.969. There was also a continuous correlation between BIS and StO2 in patients undergoing cardiac surgery. In addition, a strong correlation was found between estHb and gasHb, and between BIS and gasHb. It was therefore concluded that the combined use of BIS and tNIRS-1 is useful to evaluate cerebral hypoxia, allowing for quick response to cerebral hypoxia and reduction of hemoglobin concentration during the operation.


Assuntos
Encéfalo/metabolismo , Procedimentos Cirúrgicos Cardíacos , Monitores de Consciência , Hemoglobinas/metabolismo , Hipóxia Encefálica/diagnóstico , Hipóxia Encefálica/prevenção & controle , Complicações Intraoperatórias/diagnóstico , Complicações Intraoperatórias/prevenção & controle , Monitorização Intraoperatória/métodos , Oximetria/métodos , Consumo de Oxigênio , Biomarcadores/metabolismo , Gasometria/métodos , Humanos , Espectroscopia de Luz Próxima ao Infravermelho
11.
BMC Anesthesiol ; 21(1): 294, 2021 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-34814841

RESUMO

BACKGROUND: In this study, we aimed to analyse survey data to explore two different hypotheses; and for this purpose, we distributed an online survey to Chinese anaesthesiologists. The hypothetical questions in this survey include: (1) Chinese anaesthesiologists mainly use the depth of anaesthesia (DoA) monitors to prevent intraoperative awareness and (2) the accuracy of these monitors is the most crucial performance factor during the clinical daily practice of Chinese anaesthesiologists. METHODS: We collected and statistically analysed the response of a total of 12,750 anesthesiologists who were invited to participate in an anonymous online survey. The Chinese Society of Anaesthesiologists (CSA) trial group provided the email address of each anaesthesiologist, and the selection of respondents was random from the computerized system. RESULTS: The overall response rate was 32.0% (4037 respondents). Only 9.1% (95% confidence interval, 8.2-10.0%) of the respondents routinely used DoA monitors. Academic respondents (91.5, 90.3-92.7%) most frequently used DoA monitoring to prevent awareness, whereas nonacademic respondents (88.8, 87.4-90.2%) most frequently used DoA monitoring to guide the delivery of anaesthetic agents. In total, the number of respondents who did not use a DoA monitor and whose patients experienced awareness (61.7, 57.8-65.6%) was significantly greater than those who used one or several DoA monitors (51.5, 49.8-53.2%). Overall, the crucial performance factor during DoA monitoring was considered by 61.9% (60.4-63.4%) of the respondents to be accuracy. However, most respondents (95.7, 95.1-96.3%) demanded improvements in the accuracy of the monitors for DoA monitoring. In addition, broad application in patients of all ages (86.3, 85.2-87.4%), analgesia monitoring (80.4, 79.2-81.6%), and all types of anaesthetic agents (75.6, 74.3-76.9%) was reported. In total, 65.0% (63.6-66.5%) of the respondents believed that DoA monitors should be combined with EEG and vital sign monitoring, and 53.7% (52.1-55.2%) believed that advanced DoA monitors should include artificial intelligence. CONCLUSIONS: Academic anaesthesiologists primarily use DoA monitoring to prevent awareness, whereas nonacademic anaesthesiologists use DoA monitoring to guide the delivery of anaesthetics. Anaesthesiologists demand high-accuracy DoA monitors incorporating EEG signals, multiple vital signs, and antinociceptive indicators. DoA monitors with artificial intelligence may represent a new direction for future research on DoA monitoring.


Assuntos
Anestesia/estatística & dados numéricos , Anestesiologistas/estatística & dados numéricos , Monitorização Intraoperatória/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Adulto , Anestesia/métodos , Anestésicos/administração & dosagem , Inteligência Artificial , Atitude do Pessoal de Saúde , China , Monitores de Consciência , Feminino , Pesquisas sobre Atenção à Saúde , Humanos , Consciência no Peroperatório/prevenção & controle , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Adulto Jovem
12.
BMC Anesthesiol ; 21(1): 285, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-34781892

RESUMO

BACKGROUND: Radiofrequency catheter ablation (RFCA) as a safe and effective method has been widely used in ventricular tachycardia (VT) patients, and with which anesthesiologists frequently manage their perioperative care. The aim of this study was to investigate the effects of different anesthetic depths on perioperative RFCA and recurrence in patients who with intractable VT and could not tolerate an awake procedure. METHODS: We reviewed electronic medical records of patients with VT who underwent RFCA by general anesthesia from January 2014 to March 2019. According to intraoperative VT induction, they were divided into two groups: non-inducible group (group N) and inducible group (group I). We constructed several multivariable regression models, in which covariates included patient characteristics, comorbidities, protopathy and bispectral index (BIS) value. RESULTS: One hundred one patients were analyzed. Twenty-nine patients (28.7%) experienced VT no induction, and 26 patients (25.7%) relapsed within 1 year. Compared with group I, the proportion of patients with arrhythmogenic right ventricular cardiomyopathy in group N were higher (P < 0.05), and the recurrence rate of VT was significantly higher (51.7% vs 15.3%) (P < 0.05). The BIS value in group N was significantly lower (P < 0.01), in addition, the BIS < 40 was associated with elevated odds of VT no induction compared with a BIS > 50 (odds ratio, 6.92; 95% confidence interval, 1.47-32.56; P = 0.01). VT no induction was an independent predictor of recurrence after RFCA (odds ratio, 5.01; 95% confidence interval, 1.88-13.83; P < 0.01). CONCLUSION: Lower BIS value during VT induction in RFCA operation was associated with high risk of VT no induction, which affects postoperative outcomes. We proposed that appropriate depth of anesthesia should be maintained during the process of VT induction.


Assuntos
Anestesia Geral/métodos , Ablação por Cateter/métodos , Taquicardia Ventricular/cirurgia , Adulto , Idoso , Monitores de Consciência , Registros Eletrônicos de Saúde , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
13.
PLoS One ; 16(9): e0257467, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34520506

RESUMO

The aim of this study is to compare the effects of neuromuscular blockade (NMB) on phase lag entropy (PLE) and the bispectral index (BIS). We recorded the BIS, electromyograph (EMG) activity on a BIS monitor (EMG_BIS), PLE, and EMG activity on a PLE monitor (EMG_PLE) in 40 patients receiving general anesthesia. During the awake state, we analyzed the changes in parameters before and 2 min after the eyes were closed. During sedation, we compared the changes in the parameters before and at 4 min after injecting rocuronium (group R) or normal saline (group C) between the two groups. During anesthesia, we compared the changes in parameters before and at 4 min after injecting sugammadex (group B) or normal saline (group D) between the two groups. During the awake state, the BIS, EMG_BIS, and EMG_PLE, but not PLE, decreased significantly with closed eyes. An effect of EMG on the BIS was evident, but not on PLE. During sedation, the BIS decreased with the decrease in EMG_BIS regardless of NMB caused by rocuronium, but NMB decreased PLE, although the degree of the decrease in EMG_PLE after NMB was similar to that after placebo. To determine the effect of NMB on electroencephalograms (EEGs) in groups R and C, we plotted the power spectra before and at 4 min after injecting rocuronium or normal saline. Changes in slow and delta frequency bands were observed at 4 min after injecting rocuronium relative to before injecting rocuronium. There was no effect of EMG on either the BIS or PLE during anesthesia. In conclusion, the effect of electromyograph activity and/or neuromuscular blockade on BIS or PLE depends on the level of consciousness.


Assuntos
Monitores de Consciência , Bloqueio Neuromuscular/métodos , Adulto , Anestesia Geral , Eletroencefalografia , Eletromiografia , Feminino , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Fármacos Neuromusculares não Despolarizantes/administração & dosagem , Propofol/administração & dosagem , Rocurônio/administração & dosagem , Adulto Jovem
14.
Br J Anaesth ; 127(5): 704-712, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34465469

RESUMO

BACKGROUND: Postoperative delirium is a serious complication of surgery associated with prolonged hospitalisation, long-term cognitive decline, and mortality. This study aimed to determine whether targeting bispectral index (BIS) readings of 50 (light anaesthesia) was associated with a lower incidence of POD than targeting BIS readings of 35 (deep anaesthesia). METHODS: This multicentre randomised clinical trial of 655 at-risk patients undergoing major surgery from eight centres in three countries assessed delirium for 5 days postoperatively using the 3 min confusion assessment method (3D-CAM) or CAM-ICU, and cognitive screening using the Mini-Mental State Examination at baseline and discharge and the Abbreviated Mental Test score (AMTS) at 30 days and 1 yr. Patients were assigned to light or deep anaesthesia. The primary outcome was the presence of postoperative delirium on any of the first 5 postoperative days. Secondary outcomes included mortality at 1 yr, cognitive decline at discharge, cognitive impairment at 30 days and 1 yr, unplanned ICU admission, length of stay, and time in electroencephalographic burst suppression. RESULTS: The incidence of postoperative delirium in the BIS 50 group was 19% and in the BIS 35 group was 28% (odds ratio 0.58 [95% confidence interval: 0.38-0.88]; P=0.010). At 1 yr, those in the BIS 50 group demonstrated significantly better cognitive function than those in the BIS 35 group (9% with AMTS ≤6 vs 20%; P<0.001). CONCLUSIONS: Among patients undergoing major surgery, targeting light anaesthesia reduced the risk of postoperative delirium and cognitive impairment at 1 yr. CLINICAL TRIAL REGISTRATION: ACTRN12612000632897.


Assuntos
Anestesia Geral/efeitos adversos , Disfunção Cognitiva/epidemiologia , Delírio do Despertar/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Idoso , Anestesia Geral/métodos , Cognição , Disfunção Cognitiva/etiologia , Monitores de Consciência , Eletroencefalografia , Delírio do Despertar/prevenção & controle , Feminino , Seguimentos , Humanos , Unidades de Terapia Intensiva/estatística & dados numéricos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Fatores de Tempo
15.
Medicine (Baltimore) ; 100(29): e26576, 2021 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-34398011

RESUMO

BACKGROUND: Deep neuromuscular blockade is considered beneficial for improving the surgical space condition during laparoscopic surgery. Adequacy of the surgical space condition may affect the anesthetists' decision regarding titration of depth of anesthesia. We investigated whether deep neuromuscular blockade reduces the propofol requirement under bispectral index monitoring compared to moderate neuromuscular blockade. METHODS: Adult patients undergoing elective laparoscopic colorectal surgery were randomly allocated to a moderate or deep group. A train-of-four count of 1-2 in the moderate group, and a post-tetanic count of 1-2 in the deep group, were maintained by continuous infusion of rocuronium. The induction and maintenance of anesthesia were achieved by target-controlled infusion of propofol and remifentanil. The dose of propofol was adjusted to maintain the bispectral index in the range of 40-50. The remifentanil dose was titrated to maintain the systolic blood pressure to within 20% of the ward values. RESULTS: A total of 82 patients were included in the analyses. The mean±SD dose of propofol was 7.54 ±â€Š1.66 and 7.42 ±â€Š1.01 mg·kg-1·h-1 in the moderate and deep groups, respectively (P = .104). The mean±SD dose of remifentanil was 4.84 ±â€Š1.74 and 4.79 ±â€Š1.77 µg kg-1 h-1 in the moderate and deep groups, respectively (P = .688). In comparison to the moderate group, the deep group showed significantly lower rates of intraoperative patient movement (42.9% vs 22.5%, respectively, P = .050) and additional neuromuscular blocking agent administration (76% vs 53%, respectively, P = .007). Postoperative complications, including pulmonary complications, wound problems and reoperation, were not different between the two groups. CONCLUSION: Deep neuromuscular blockade did not reduce the bispectral index-guided propofol requirement compared to moderate neuromuscular blockade during laparoscopic colon surgery, despite reducing movement of the patient and the requirement for a rescue neuromuscular blocking agent. TRIAL REGISTRATION: Clinicaltrials.gov (NCT03890406).


Assuntos
Monitores de Consciência/normas , Monitoração Neuromuscular/normas , Propofol/administração & dosagem , Adulto , Idoso , Monitores de Consciência/estatística & dados numéricos , Relação Dose-Resposta a Droga , Feminino , Humanos , Hipnóticos e Sedativos/administração & dosagem , Hipnóticos e Sedativos/uso terapêutico , Masculino , Pessoa de Meia-Idade , Bloqueio Neuromuscular/classificação , Bloqueio Neuromuscular/métodos , Monitoração Neuromuscular/métodos , Propofol/uso terapêutico , Estudos Prospectivos , República da Coreia , Estatísticas não Paramétricas
16.
BMC Anesthesiol ; 21(1): 201, 2021 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-34376153

RESUMO

BACKGROUND: Administration of an optimal dose of anesthetic agent to ensure adequate depth of hypnosis with the lowest risk of adverse effects to the fetus is highly important in cesarean section. Sodium thiopental (STP) is still the first choice for induction of anesthesia in some countries for this obstetric surgery. We aimed to compare two doses of STP with regarding the depth of anesthesia and the condition of newborn infants. METHODS: In this clinical trial, parturient undergoing elective Caesarian section were randomized into two groups receiving either low-dose (5 mg/kg) or high-dose (7 mg/kg) STP. Muscle relaxation was provided with succinylcholine 2 mg/kg and anesthesia was maintained with O2/N2O and sevoflurane. The depth of anesthesia was evaluated using isolated forearm technique (IFT) and bispectral index (BIS) in various phases. Additionally, infants were assessed using Apgar score and neurobehavioral test. RESULTS: Forty parturient were evaluated in each group. BIS was significantly lower in high-dose group at skin incision to delivery and subcutaneous and skin closure. Also, significant differences were noticed in IFT over induction to incision and incision to delivery. Apgar score was significantly lower in high-dose group at 1 min after delivery. Newborn infants in low-dose group had significantly better outcomes in all three domains of the neurobehavioral test. CONCLUSION: 7 mg/kg STP is superior to 5 mg/kg in creating deeper hypnosis for mothers. However, it negatively impacts Apgar score and neurobehavioral test of neonates. STP seems to has dropped behind as an acceptable anesthetic in Cesarean section. TRIAL REGISTRATION: IRCT No: 2016082819470 N45 , 13/03/2019.


Assuntos
Anestesia Obstétrica/métodos , Anestésicos Intravenosos/administração & dosagem , Cesárea/métodos , Tiopental/administração & dosagem , Adulto , Anestésicos Intravenosos/farmacologia , Índice de Apgar , Monitores de Consciência , Relação Dose-Resposta a Droga , Feminino , Humanos , Recém-Nascido , Gravidez , Sevoflurano/administração & dosagem , Método Simples-Cego , Succinilcolina/administração & dosagem , Tiopental/farmacologia , Adulto Jovem
17.
Br J Anaesth ; 127(3): 386-395, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34243940

RESUMO

BACKGROUND: Intraoperative EEG suppression duration has been associated with postoperative delirium and mortality. In a clinical trial testing anaesthesia titration to avoid EEG suppression, the intervention did not decrease the incidence of postoperative delirium, but was associated with reduced 30-day mortality. The present study evaluated whether the EEG-guided anaesthesia intervention was also associated with reduced 1-yr mortality. METHODS: This manuscript reports 1 yr follow-up of subjects from a single-centre RCT, including a post hoc secondary outcome (1-yr mortality) in addition to pre-specified secondary outcomes. The trial included subjects aged 60 yr or older undergoing surgery with general anaesthesia between January 2015 and May 2018. Patients were randomised to receive EEG-guided anaesthesia or usual care. The previously reported primary outcome was postoperative delirium. The outcome of the current study was all-cause 1-yr mortality. RESULTS: Of the 1232 subjects enrolled, 614 subjects were randomised to EEG-guided anaesthesia and 618 subjects to usual care. One-year mortality was 57/591 (9.6%) in the guided group and 62/601 (10.3%) in the usual-care group. No significant difference in mortality was observed (adjusted absolute risk difference, -0.7%; 99.5% confidence interval, -5.8% to 4.3%; P=0.68). CONCLUSIONS: An EEG-guided anaesthesia intervention aiming to decrease duration of EEG suppression during surgery did not significantly decrease 1-yr mortality. These findings, in the context of other studies, do not provide supportive evidence for EEG-guided anaesthesia to prevent intermediate term postoperative death. CLINICAL TRIAL REGISTRATION: NCT02241655.


Assuntos
Anestesia/mortalidade , Eletroencefalografia , Monitorização Neurofisiológica Intraoperatória , Complicações Pós-Operatórias/mortalidade , Acidentes por Quedas , Idoso , Anestesia/efeitos adversos , Monitores de Consciência , Delírio/etiologia , Delírio/mortalidade , Eletroencefalografia/instrumentação , Feminino , Humanos , Monitorização Neurofisiológica Intraoperatória/instrumentação , Masculino , Pessoa de Meia-Idade , Missouri , Complicações Cognitivas Pós-Operatórias/etiologia , Complicações Cognitivas Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/etiologia , Valor Preditivo dos Testes , Qualidade de Vida , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
18.
BMC Vet Res ; 17(1): 201, 2021 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-34049559

RESUMO

BACKGROUND: The bispectral index (BIS) is an anaesthesia monitoring technique able to assess the level of central nervous system depression in humans and various animal species. In birds, it has been validated in chickens undergoing isoflurane anaesthesia. The aim of this study was to evaluate in an avian species the influence of isoflurane and sevoflurane on BIS, each at different minimum anaesthetic concentrations (MAC) multiples, alone or combined with butorphanol or medetomidine. Ten chickens (5 males and 5 females) underwent general anaesthesia with isoflurane or sevoflurane alone, and combined with either intramuscular administration of butorphanol (1 mg/kg) or medetomidine (0.1 mg/kg), in a prospective and cross-over study (i.e., 6 treatments per animal). BIS measurements were compared to heart rate (HR), non-invasive blood pressure (NIBP) and to a visual analogue scale (VAS) of anaesthesia depth. RESULTS: HR was significantly increased, and both NIBP and VAS were significantly reduced, with higher gas concentrations. NIBP (but not HR or VAS) was additionally affected by the type of gas, being lower at higher concentrations of sevoflurane. Butorphanol had no additional effect, but medetomidine led to differences in HR, NIBP, and in particular a reduction in VAS. With respect to deeper level of hypnosis at higher concentrations and the absence of difference between gases, BIS measurements correlated with all other measures (except with HR, where no significant relationship was found) The difference in BIS before (BISpre) and after stimulation (BISpost) did not remain constant, but increased with increasing MAC multiples, indicating that the BISpost is not suppressed proportionately to the suppression of the BISpre values due to gas concentration. Furthermore, neither butorphanol nor medetomidine affected the BIS. CONCLUSIONS: The difference of degree of central nervous system depression monitored by BIS compared with neuromuscular reflexes monitored by VAS, indicate that BIS records a level of anaesthetic depth different from the one deducted from VAS monitoring alone. BIS provided complementary information such as that medetomidine suppressed spinal reflexes without deepening the hypnotic state. As a consequence, it is concluded that BIS improves the assessment of the level of hypnosis in chickens, improving anaesthesia monitoring and anaesthesia quality in this species.


Assuntos
Butorfanol/farmacologia , Galinhas , Monitores de Consciência/veterinária , Isoflurano/farmacologia , Medetomidina/farmacologia , Sevoflurano/farmacologia , Anestésicos Combinados/farmacologia , Animais , Estudos Cross-Over , Feminino , Frequência Cardíaca/efeitos dos fármacos , Masculino , Estudos Prospectivos
19.
Int J Med Sci ; 18(10): 2117-2127, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33859518

RESUMO

Background: Assessment the depth of dexmedetomidine sedation using electroencephalographic (EEG) features can improve the quality of procedural sedation. Previous volunteer studies of dexmedetomidine-induced EEG changes need to be validated, and changes in bicoherence spectra during dexmedetomidine sedation has not been revealed yet. We aimed to investigate the dexmedetomidine-induced EEG change using power spectral and bicoherence analyses in the clinical setting. Patients and Methods: Thirty-six patients undergoing orthopedic surgery under spinal anesthesia were enrolled in this study. Dexmedetomidine sedation was conducted by the stepwise increase in target effect site concentration (Ce) while assessing sedation levels. Bispectral index (BIS) and frontal electroencephalography were recorded continuously, and the performance of BIS and changes in power and bicoherence spectra were analyzed with the data from the F3 electrode. Results: The prediction probability values for detecting different sedation levels were 0.847, 0.841, and 0.844 in BIS, 95% spectral edge frequency, and dexmedetomidine Ce, respectively. As the depth of sedation increased, δ power increased, but high ß and γ power decreased significantly (P <0.001). α and spindle power increased significantly under light and moderate sedation (P <0.001 in light vs baseline and deep sedation; P = 0.002 and P <0.001 in moderate sedation vs baseline and deep sedation, respectively). The bicoherence peaks of the δ and α-spindle regions along the diagonal line of the bicoherence matrix emerged during moderate and deep sedation. Peak bicoherence in the δ area showed sedation-dependent increases (29.93%±7.38%, 36.72%±9.70%, 44.88%±12.90%; light, moderate, and deep sedation; P = 0.008 and P <0.001 in light sedation vs moderate and deep sedation, respectively; P = 0.007 in moderate sedation vs deep sedation), whereas peak bicoherence in the α-spindle area did not change (22.92%±4.90%, 24.72%±4.96%, and 26.96%±8.42%, respectively; P=0.053). Conclusions: The increase of δ power and the decrease of high-frequency power were associated with the gradual deepening of dexmedetomidine sedation. The δ bicoherence peak increased with increasing sedation level and can serve as an indicator reflecting dexmedetomidine sedation levels.


Assuntos
Raquianestesia/métodos , Dexmedetomidina/administração & dosagem , Hipnóticos e Sedativos/administração & dosagem , Monitorização Neurofisiológica/métodos , Dor Processual/prevenção & controle , Adulto , Idoso , Estado de Consciência/efeitos dos fármacos , Monitores de Consciência , Sedação Profunda/métodos , Relação Dose-Resposta a Droga , Eletroencefalografia , Feminino , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Monitorização Neurofisiológica/instrumentação , Procedimentos Ortopédicos/efeitos adversos , Dor Processual/etiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...